  • • Detection Gas: benzene,toluene,methanal,alcohol,smoke
  • • Detection Range:0.5~1000ppm(alcohol)
  • • Application:It is used in occasions such as household and office for harmful gas detection,automatic exhaust device,air cleaner & etc.

We're here to help: Easy ways to get the answers you need.

  • Principle Introduction
Principle Introduction:
 MP801 gas sensor is for air quality,It adopts multilayer thick film manufacturing technolgy. The heater and metal oxide semiconductor material on the ceramic substrate of subminiature Al2O3 are fetched out by electrode down-lead, encapsulated in metalsocket and cap. Conductivity of the sensor is affected by theconcentration of target gas. The higher the concentration is, the higher conductivity of sensor gets. Users can adopt simple circuit to convert to convert variation of conductivity into output signal corresponding to gas concentration.
Applications :
 It is used in occasions such as household and office for harmful gas detection,automatic exhaust device,air cleaner & etc.
Technical parameters :

Tips:For more parameter information, please refer to the latest manual provided by salesman.

 
Model MP801
Sensor Type Semiconductor flat surfaced sensor
Standard Encapsulation Metal Cap
Detection Gas benzene,toluene,methanal,alcohol,smoke
Detection range 0.5~1000ppm(alcohol)
Standard circuit Loop voltage VC / VH VC:≤24V DC   VH:5.0V±0.1V AC or DC
Load resistance RL Adjustable
sensor features in standard test condition Heating resistance RH 95Ω±10Ω(Room Tem.)
Heating consumption PH ≤300mW
Surface resistance RS 1KΩ~15KΩ(in 10ppm alcohol)
Sensitivity S Rs(in air)/Rs(in 10ppm alcohol)≥2
Concentration slope α ≤0.6(R 50ppm/R 10ppm alcohol)
Standard condition of test Temperature, humidity 20℃±2℃;65%±5%RH
Standard test circuit VC/VH :5.0V±0.1V
Warm-up time More than 48 hours