GM-402B MEMS Combustible Gas Sensor

  • • MEMS technology, Strong construction
  • • High sensitivity to combustible gases
  • • Small sizes and low power consumption
  • • Fast response and resume
  • • Simple drive circuit, Long lifespan

We're here to help: Easy ways to get the answers you need.

  • Principle Introduction
Principle Introduction:
MEMS combustible gas sensor is using MEMS micro-fabrication hot plate on a Si substrate base, gas-sensitive materials used in the clean air with low conductivity metal oxide semiconductor material. When the sensor exposed to gas atmosphere, the conductivity is changing as the detected gas concentration in the air. The higher the concentration of the gas, the higher the conductivity. Use simple circuit can convert the change of conductivity of the gas concentration corresponding to the output signal.
Applications :
Gas leak detection for mobile phones, computers and other consumer electronics applications; also apply for home, commercial use of the combustible gas leakage monitoring devices, gas leak detectors, fire / security detection system.
Technical parameters :

Tips:For more parameter information, please refer to the latest manual provided by salesman.

 

Part No.

GM-402B

Sensor Type

MEMS

Standard Encapsulation

Ceramic

Detection Gas

CH4, C3H8 &etc.

Detection Range

1~10000ppm (C3H8)

Standard Circuit

Conditions

Loop Voltage

VC

≤24V DC

Heater Voltage

VH

2.8V±0.1V AC or DC

Load Resistance

RL

Adjustable

Sensor character under standard test conditions

Heater Resistance

RH

80Ω±20Ω(room temperature)

Heater consumption

PH

≤80mW

sensitive materials resistance

RS

1KΩ~30KΩ(in 5000ppm CH4)

Sensitivity

S

R0(in air)/Rs(in 5000ppmCH4)≥2

Concentration slope

α

≤0.9(R5000ppm/R1000ppmCH4)

Standard test conditions

Temp. Humidity

20℃±2℃;55%±5%RH

Standard test circuit

VH:2.8V±0.1V;VC:5.0V±0.1V

Reference Circuit :
 