Target: CO2. PM2.5. CH2O. O3. CO. TVOC. NO2. Temperature. Humidity
Model: ZPHS01B
Detection range: See Manul
Detection principle: Module
Characteristics: See Manul
Size: 135 x 50 x 26.2mm (L x W x H)

ZPHS01B Manual download
Get Price Whatsapp

Description

ZPHS01B is a multi-in-one air quality module, integrating laser dust sensor, infrared carbon dioxide sensor, electrochemical formaldehyde sensor, electrochemical ozone sensor, electrochemical carbon monoxide sensor, VOC sensor, NO2 sensor and temperature and humidity sensor. It can accurately measure the concentration of various gases in the air, with UART (TTL level) communication interface.

Application

  • Gas detector
  • Air conditioner
  • Air quality monitoring
  • Air purifier
  • HVAC system
  • Smart home

Features

 

Specifications

Model ZPHS01B
Target Gas CO2.PM2.5.CH2O. O3. CO.TVOC. NO2.Temperature.Humidity
Working voltage 5V (DC)
Average Current <300 mA
Peak Current <500 mA
Physical interface XH2.54-4P
Interface level  3V(compatible with 3.3V)
Output signal UART (TTL)
PM2.5 Range 0~1000μg/m3
Particle size range 0.3-10μm(PM1.0, PM2.5, PM10)
Accuracy ±15 ug/m3(when concentration is≤100ug/m3); ±15% (when concentration is >100ug/m3)
Response time T90 < 45s
Sampling method Fan extraction
MTTF Continuous uninterrupted > 10000h
CO2 Range 0~5000 ppm
Accuracy ±(50ppm+5% of reading value)
Warm-up time 3min
Response time T90 < 120s
Sampling method Diffuse
Lifespan > 5 years
CH2O range  0~6.250 mg/m3
accuracy ± 0.03 mg/m3(when concentration is≤0.2mg/m3); ± 20% reading value (when concentration is >0.2mg/m3)
Warm-up ≤ 3min
Response time ≤ 60s
Recovery time ≤ 60s
Sampling method Diffuse
Life span 5 years (18~25℃in clean air)
TVOC Range 0~3 grades
Warm-up ≤3min
Response time ≤20s
Recovery time ≤60s
Sampling method Diffuse
Sensitivity attenuation ≤1% /year
O3 Range 0~10 ppm
Resolution 0.01 ppm
Accuracy ± 0.1ppm, when the concentration is≤1ppm; ±20% full range, when the concentration is over 1ppm;
Warm-up ≤3min
Response time ≤90s
Recovery time ≤90s
Sampling method Diffuse
Life span 2 years(18~25℃in clean air)
CO Range 0~500 ppm
Resolution 0.1 ppm
Accuracy ± 10% reading value
Warm-up ≤30s
Response time ≤30s
Recovery time ≤30s
Sampling method Diffuse
Life span 3~5 years (in air)
NO2 Range 0.1~10 ppm
Resolution 0.05ppm
Warm-up ≤3min
Response time ≤120s
Recovery time ≤90s
Temperature Range -20~65℃
Accuracy ±0.5℃(0-65℃)
Humidity Range 0~100%RH
Accuracy ±3%RH
Working temperature -10~50℃
Working humidity 15~80% RH(no condensing)
Storage temperature(recommend) 0~25℃
Storage humidity (recommend) 0~80% RH
Dimensions 135 x50 x 26.2mm (L x W x H)

* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.

Technical Support:

Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.

The sensors don't have sleeping mode. It can be set in program if needed.

All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.

The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.

However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.

15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.

Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.

Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.

Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com

Due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately. But we will reply to your inquiry in 24 business hours.