ZPHS01B is a multi-in-one air quality module, integrating laser dust sensor, infrared carbon dioxide sensor, electrochemical formaldehyde sensor, electrochemical ozone sensor, electrochemical carbon monoxide sensor, VOC sensor, NO2 sensor and temperature and humidity sensor. It can accurately measure the concentration of various gases in the air, with UART (TTL level) communication interface.
Application
- Gas detector
- Air conditioner
- Air quality monitoring
- Air purifier
- HVAC system
- Smart home
Features
Specifications
Model | ZPHS01B | |
Target Gas | CO2.PM2.5.CH2O. O3. CO.TVOC. NO2.Temperature.Humidity | |
Working voltage | 5V (DC) | |
Average Current | <300 mA | |
Peak Current | <500 mA | |
Physical interface | XH2.54-4P | |
Interface level | 3V(compatible with 3.3V) | |
Output signal | UART (TTL) | |
PM2.5 | Range | 0~1000μg/m3 |
Particle size range | 0.3-10μm(PM1.0, PM2.5, PM10) | |
Accuracy | ±15 ug/m3(when concentration is≤100ug/m3); ±15% (when concentration is >100ug/m3) | |
Response time | T90 < 45s | |
Sampling method | Fan extraction | |
MTTF | Continuous uninterrupted > 10000h | |
CO2 | Range | 0~5000 ppm |
Accuracy | ±(50ppm+5% of reading value) | |
Warm-up time | 3min | |
Response time | T90 < 120s | |
Sampling method | Diffuse | |
Lifespan | > 5 years | |
CH2O | range | 0~6.250 mg/m3 |
accuracy | ± 0.03 mg/m3(when concentration is≤0.2mg/m3); ± 20% reading value (when concentration is >0.2mg/m3) | |
Warm-up | ≤ 3min | |
Response time | ≤ 60s | |
Recovery time | ≤ 60s | |
Sampling method | Diffuse | |
Life span | 5 years (18~25℃in clean air) | |
TVOC | Range | 0~3 grades |
Warm-up | ≤3min | |
Response time | ≤20s | |
Recovery time | ≤60s | |
Sampling method | Diffuse | |
Sensitivity attenuation | ≤1% /year | |
O3 | Range | 0~10 ppm |
Resolution | 0.01 ppm | |
Accuracy | ± 0.1ppm, when the concentration is≤1ppm; ±20% full range, when the concentration is over 1ppm; | |
Warm-up | ≤3min | |
Response time | ≤90s | |
Recovery time | ≤90s | |
Sampling method | Diffuse | |
Life span | 2 years(18~25℃in clean air) | |
CO | Range | 0~500 ppm |
Resolution | 0.1 ppm | |
Accuracy | ± 10% reading value | |
Warm-up | ≤30s | |
Response time | ≤30s | |
Recovery time | ≤30s | |
Sampling method | Diffuse | |
Life span | 3~5 years (in air) | |
NO2 | Range | 0.1~10 ppm |
Resolution | 0.05ppm | |
Warm-up | ≤3min | |
Response time | ≤120s | |
Recovery time | ≤90s | |
Temperature | Range | -20~65℃ |
Accuracy | ±0.5℃(0-65℃) | |
Humidity | Range | 0~100%RH |
Accuracy | ±3%RH | |
Working temperature | -10~50℃ | |
Working humidity | 15~80% RH(no condensing) | |
Storage temperature(recommend) | 0~25℃ | |
Storage humidity (recommend) | 0~80% RH | |
Dimensions | 135 x50 x 26.2mm (L x W x H) |
* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.
Technical Support:
Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.
The sensors don't have sleeping mode. It can be set in program if needed.
All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.
The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.
However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.
15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.
Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.
Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.
Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com