Target: | particulate matters PM1.0, PM2.5, PM4.25, PM10 |
Model: | ZH07 |
Detection range: | 0-1000μg/m³ |
Detection principle: | Laser |
Characteristics: | Good consistency, Real time response, Low power consumption, RESET compliant |
Size: | 48×40×12.5mm(L×W×H) |
Output signal: | UART/PWM Output |
Resolution and accuracy: | 0-100 μg/m³:±15μg/m³ 101-1000 μg /m³: ± 15% Reading |
Response time: | T90<30s |
ZH07 Manual download
Get Price Whatsapp
Description
Laser Dust sensor module ZH07 is a common type, small size sensor, using laser scattering principle to detect the dust particles in air, with good consistency and stability. It is easy to use, with UART & PWM output.
Application
- Air purifiers;
- HVAC, ventilation systems;
- Portable instrument;
- Air quality monitoring equipment;
- Air conditioner;
- Smart buildings and smart home.
Features
- Good consistency
- Real time response
- Accurate data
- Low power consumption
- Minus resolution of particle diameter 0.3 µm
Specifications
Model | ZH07 |
Detectable particle diameter range | 0.3-10μm |
Effective Range | 0-1000μg/m³ |
Detection Interval | 1s |
PM2.5 Detection Accuracy | 0-100 μg/m³:±15μg/m³ 101-1000 μg /m³: ± 15% Reading (Test Condition: 25 ± 2 ℃, 50 ± 10% RH,TSI8530, Cigarette, GBT18801-2015) |
Preheating Time | 30s |
Output | UART_TTL Output (3.3V level, default) |
PWMOutput (3.3V level, default) | |
Working Voltage | 4.8V~5.5V(DC) |
Working Current | <120mA |
DormancyCurrent | <20mA |
Response Time | T90<30s |
Working Humidity | 0~80%RH(No Condensation) |
Working Tem. | -10~60℃ |
Storage Tem. | -30~70℃ |
Dimension | 48×40×12.5mm(L×W×H) |
Weight | <30g |
MTTF | Continuous > 10000H |
* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.
Technical Support:
Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.
The sensors don't have sleeping mode. It can be set in program if needed.
All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.
The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.
However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.
15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.
Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.
Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.
Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com
Due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately. But we will reply to your inquiry in 24 business hours.