Target: Hydrogen (H2)
Model: ZC61
Detection range: 0-40000ppm
Detection principle: Catalytic combustion
Characteristics: MEMS process,Intelligent algorithms
Response time: T90<3s
Notes: IATF16949 compliant

ZC61 Manual download
Get Price Whatsapp

Description

ZC61 hydrogen leakage sensor is mainly used in the monitoring of hydrogen leakage in the hydrogen fuel cell engine and hydrogen supply pipeline system. The catalytic combustion sensor of the MEMS process is used to detect the hydrogen concentration. This sensor is a high-performance module made by closely combining mature detection technology with high-quality design circuits.

Application

Hydrogen energy vehicles, hydrogen energy preparation, hydrogen energy storage, and hydrogen energy transportation.

Features

  • MEMS process
  • Intelligent algorithms
  • Anti-electromagnetic interference
  • CAN interface output
  • Excellent repeatability and stability
  • Long service life

Specifications

Detection principle Catalytic combustion
Detection target H2
Detection range 0~40000ppm
Resolution ratio 1ppm
Detection accuracy ±10% (>1%VOL(H2))
Operating voltage DC (9~36)V
Operating current <15mA
Power consumption <0.2W
Start-up time <1s
Response time T90<3s
Recovery time <10s
IP rating IP68
Operating temperature  -40℃~85℃ 
Storage temperature  -40℃~125℃ 
Operating humidity 0~95%RH(No condensation)
Output mode PWM/CAN/Analog quantity(Customizable)

* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.

Technical Support:

Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.

The sensors don't have sleeping mode. It can be set in program if needed.

All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.

The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.

However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.

15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.

Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.

Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.

Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com

Due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately. But we will reply to your inquiry in 24 business hours.

LEADING GAS SENSING SOLUTION SUPPLIER

RELATED PRODUCTS