Target: Hydrocarbon flammable gases
Model: MH-T4041A
Detection range: 0~10% Vol optional(refer to sheet 2)
Detection principle: NDIR
Characteristics: High sensitivity, high resolution, fast response time
Size: Φ20mm×21.7mm
Response time: T90<15s

MH-T4041A Manual download
Get Price Whatsapp

Description

MH-T4041A low-power infrared gas sensor is a general-purpose intelligent infrared gas sensor (hereinafter referred to as the sensor), using non-dispersive infrared (NDIR) principle to detect hydrocarbon combustible gases in the air. It has good selectivity, ultra-low power consumption, no oxygen dependence, stable performance, long life, and built-in temperature compensation.The sensor is a compact and high performance sensor which combines the mature infrared absorption gas detection technology with micro-machining and excellent circuit design. It is easy to use, can directly replace catalytic combustion elements, so it is widely used in various occasions where combustible and explosive gases exist.

Application

  • HVAC Refrigeration and Indoor Air Quality monitoring
  • Industrial Process and safety protection monitoring
  • Agricultural and animal husbandry production process monitoring

Features

  • High sensitivity, high resolution, fast response time, ultra-low power consumption
  • Provides a variety of output modes, such as UART and analog voltage
  • Temperature compensation, excellent linear output, excellent stability, long service life
  • Anti-water vapor interference, no poisoning, can directly replace the catalytic combustion principle sensor

Specifications

Model No. MH-T4041A
Detection Gas Hydrocarbon flammable gases
Working voltage 3.3V~5.5V DC(powered by the safety grid)
Average Current <0.8mA
Deteciton Range 0~10% Vol optional(refer to sheet 2)
Interface level 3V
  Output signal UART(3.0Vor 5.0V)
Preheat Time <10s
Reponse Time T90<15s
Working Temperature -20℃  ~60 ℃
Working Humidity 0~95%RH(non-condensing)
Dimension Φ20mm×21.7mm
Weight 8g
Life time >5 years
Protection Level IP54
Power end, communication end Intrinsicsafety parameter Ui=7.5VDC,Ii=200mA, Pi=375mW,Ci=4.5μF,Li=0mH

Sheet 2
Gas Molecular formula Range Resolution Decimal place Accuracy Note
  Methane   CH4 0~5.00% Vol   0.01% Vol 2 decimal     ±3%FS(10℃-40℃)   ±5%FS(-20℃-10℃, 40℃-60℃)        
0~10.00% Vol 2 decimal
Propane C3H8 0~100% LEL 1% LEL None
Isobutane C4H10 0~100% LEL 1% LEL None

* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.

Technical Support:

Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.

The sensors don't have sleeping mode. It can be set in program if needed.

All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.

The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.

However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.

15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.

Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.

Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.