Target: Combustible gas
Model: MH-742B
Detection range: 0~100% Vol optional
Detection principle: non-dispersive infrared (NDIR) principle
Characteristics: 1.High sensitivity, high resolution, low power consumption; 2.Widely used for industrial field instrumentation, industrial-process control and safety protection
Size: Φ39×44 mm
Working conditions: 4.5~5.5 V DC
Measurement range: Please refer to the instruction
Resolution and accuracy: Please refer to the instruction
Response time: T90 < 30 s
Notes: This product has been discontinued, Updated Model No.: MH-T7042A

MH-742B Manual download
Get Price Whatsapp

Description

MH-742B is a universal type intelligent sensor to detect combustible gas,taking advantage of non-dispersive infrared (NDIR) principle. With high selectivity, no oxygen dependence, high performance and long lifespan features, MH-742B also has built-in temperature compensation feature. MH-742B is a compact and high-performance sensor based on infrared absorption of gas detection technology, micro-machining and sophisticated circuit design.

Application

Widely used for industrial field instrumentation, industrial-process control and safety protection

Features

  • High sensitivity, high resolution, low power consumption
  • Output method: UART, analog voltage signal, etc.
  • Quick response
  • Temperature compensation, excellent linear output
  • Excellent stability, Long lifespan
  • Anti-poisons, anti-vapor interference 

Specifications

 

Table 1 Technical Index

Product Model MH-742B
Gas Detected Combustible Gas (See Table 2 for details)
Working Voltage 4.5 V ~ 5.5V DC
Average Current < 100mA
Interface Level 3.3V
Measurement Range 0~100%VOL optional (view table 2)
Output Signal UART
0.4-2V DC
Warm-up Time <2min
Response Time T90 < 30s
Working Temperature -40℃ ~ 70℃
Working Humidity 0 to 95%RH, non-condensing
Dimension Φ39×44mm
Weight 280g
Life span >5 years
Protected Class IP54

 

 

 

Table 2 Measurement Range and Accuracy

Gas name Molecular Formula Range Resolution Note
Methane CH4 0~5% Vol 0.01% Vol Temperature compensation
Methane CH4 0~10% Vol 0.01% Vol Temperature compensation
Methane CH4 0~100% Vol 0.1% Vol Temperature compensation
Propane C3H8 0~2.1% Vol 0.01% Vol Temperature compensation
Propane C3H8 0~100% Vol 0.1% Vol Temperature compensation
Methyl chloride CH3CL 0~8.1% Vol 0.01% Vol Temperature compensation
Methyl chloride CH3CL 0~100% Vol 0.1% Vol Temperature compensation
Acetylene C2H2 0~2.1% Vol 0.02% Vol Temperature compensation
Propylene C3H6 0~2.0% Vol 0.02% Vol Temperature compensation
Ethylene C2H4 0~2.7% Vol 0.027% Vol Temperature compensation
Ethane CH3CH3 0~3.0% Vol 0.03% Vol Temperature compensation
Iso-butane C4H10 0~1.8% Vol 0.018% Vol Temperature compensation
Gasoline C3-C12 0~1.1% Vol 0.01% Vol Temperature compensation
Cyclopentane C5H10 0~1.4% Vol 0.01% Vol No temperature compensation
Cyclohexane C6H12 0~1.3% Vol 0.01% Vol No temperature compensation
Methanol CH3OH 0~6.7% Vol 0.06% Vol No temperature compensation
Dichloromethane CH2CL2 0~15% Vol 0.15% Vol No temperature compensation
Benzene C6H6 0~1.2% Vol 0.012% Vol No temperature compensation
Toluene C7H8 0~1.2% Vol 0.012% Vol No temperature compensation
Alcohol C2H5OH 0~3.3% Vol 0.033% Vol No temperature compensation
Ethylene oxide C2H4O 0~3.0% Vol 0.03% Vol No temperature compensation
Epichlorohydrin C3H5CLO 0~3.8% Vol 0.038% Vol No temperature compensation
Ehloropropene C3H5CL 0~2.9% Vol 0.029% Vol No temperature compensation
Pentane C5H12 0~1.4% Vol 0.014% Vol No temperature compensation
Ethyl acetate C4H8O2 0~2.0% Vol 0.02% Vol No temperature compensation

 

* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.

Technical Support:

Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.

The sensors don't have sleeping mode. It can be set in program if needed.

All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.

The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.

However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.

15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.

Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.

Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.

Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com

Due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately. But we will reply to your inquiry in 24 business hours.

LEADING GAS SENSING SOLUTION SUPPLIER