Target: CH4
Model: MH-440D
Detection range: 0~10% Vol optional
Detection principle: non-dispersive infrared (NDIR) principle
Characteristics: 1. High sensitivity, high resolution, fast response;2. Output method: UART, analog voltage signal;3. Temperature compensation, excellent linear output;4. Excellent stability, Long lifespan;5. Anti-poisons, anti-vapor interference;6. Can replace catalytic
Size: Φ20×22.6mm
Working conditions: 3.6~5 .0V DC(Need to be powered by safety barrier)
Measurement range: 0~5.00% Vol
0~10.00% Vol
100%LEL
Resolution and accuracy: 0.01% Vol, 1%LEL
Response time: T90 < 30 s
Notes: This product has been discontinued and find more MH-441D

MH-440D Manual download
Get Price Whatsapp

Description

MH-440D infrared gas sensor is a miniature universal intelligent sensor, which adopts NDIR theory to detect concentration of CH4 in air and has good selectivity, stable performance, long life, also is independent of Oxygen. The inside temperature sensor could be used for temperature compensation. This miniature infrared gas sensor is developed by the tight integration of mature infrared absorbing gas detection technology, micro machine workout and superior circuit design.
It is convenient in use and also instead of catalytic component directly, widely used in various occasions with flammable and explosion hazard gas. 

Application

Widely used for HVAC refrigeration, air monitoring indoor, industrial-process control and safety protection, agriculture and animal husbandry. 

Features

  • High sensitivity, high resolution, fast response
  • Output method: UART, analog voltage signal
  • Temperature compensation, excellent linear output
  • Excellent stability, Long lifespan
  • Anti-poisons, anti-vapor interference
  • Can replace catalytic type gas sensor directly

Specifications

Detection gas Methane (CH4)
Working Voltage 3.6~5.0VDC (Need to be powered by safety barrier)
Average Current <85mA
Interface Level 3.0V
Detection range 0~10%vol (selectable, refer to fig2.)
Output Signal UART(3.0V)
0.4~2.0VDC
Warm-up Time 3 min
Response Time T90<30 seconds
Working Temperature -20°C ~ 60°C
Working Humidity 0~95%RH (no condensation)
Sizes Φ20×22.6mm
Weight 35g
Life Time >5 years
Defense Grade IP54
Power, Communication Terminal Intrinsic Safety Ui=7.5VDC,Ii=265mA, Pi=0.5W,Ci=10μF,Li=0mH

* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.

Technical Support:

Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.

The sensors don't have sleeping mode. It can be set in program if needed.

All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.

The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.

However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.

15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.

Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.

Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.

Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com

Due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately. But we will reply to your inquiry in 24 business hours.

LEADING GAS SENSING SOLUTION SUPPLIER