Target: CO Carbon Monoxide Gas
Model: MEs-CO
Detection range: 0~1000ppm
Detection principle: Electrochemical
Characteristics: Low consumption, High precision
Resolution and accuracy: (1.0~2.0) nA/ppm
Response time: <30S
Notes: Certification: EN50291-1

MEs-CO Manual download
Get Price Whatsapp

Description

MEs-CO Carbon monoxide sensor is a fuel cell type sensor. Carbon monoxide and oxygen undergo corresponding REDOX reaction on the working electrode and the opposite electrode and release charge to form current. The current generated is proportional to the concentration of carbon monoxide and follows Faraday's law.

Application

Widely suitable for carbon monoxide concentration detection in smart homes, commercial buildings, underground garages, fire monitoring and other fields

Features

  • Low consumption
  • High precision
  • High sensitivity
  • Wide linear range
  • Good anti-interference ability
  • Long lifespan
  • Excellent repeatability and stability 

Specifications

Detection gas CO
Measurement Range 0~1000ppm
Max detecting concentration 2000ppm
Sensitivity (1.0~2.0) nA/ppm
Resolution 1ppm
Response time(T90) <30S
Load resistance(recommended) 500/1k/2k Ω
Repeatability <3﹪output value
Output Linearity linear
Zero drift(-20℃~40℃) ≤10ppm
Temperaturerange -20℃~80℃
Humidityrange 15﹪~90﹪RH
Pressure range standard atmosphere±10%
Lifespan 10 years

* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.

Technical Support:

Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.

The sensors don't have sleeping mode. It can be set in program if needed.

All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.

The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.

However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.

15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.

Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.

Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.

Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com

Due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately. But we will reply to your inquiry in 24 business hours.