MEs-CO Carbon Monoxide sensor
- CO Carbon Monoxide Gas
- 0~1000ppm
- Read More
MEu-CO Carbon Monoxide Sensor
- Carbon monoxide(CO)
- 0~1000ppm
- Read More
Electrochemical Carbon Monoxide Gas Sensor Module ZE730-CO
- Carbon Monoxide
- 0~1000ppm
- Read More
MEu-2CO Carbon Monoxide Sensor Over 7 years lifetime
- Carbon monoxide(CO)
- 0~500ppm,Max Range 1000ppm
- Read More
ME2-CO-Φ14x5 Carbon Monoxide Gas Sensor
- CO
- 0~1000ppm
- Read More
MQ-7B Semiconductor Sensor for Carbon Monoxide
- CO
- 10-500ppm
- Read More
MQ-9B Semiconductor Sensor for Carbon Monoxide
- CO,CH4
- CO(10-500ppm),CH4(300-10000ppm)
- Read More
Electrochemical CO Module ZE07-CO
- CO
- 0~500ppm
- Read More
Electrochemical Detection Module ZE03
- CO,O2,NH3,H2S,NO2,O3,SO2, CL2,HF,H2,PH3,HCL, etc.
- See manual
- Read More
Electrochemical Detection Module ZE03G
- CO, H2S, NH3, CL2, SO2, NO2, O2 and other gases
- See manual
- Read More
ME4-CO Carbon Monoxide Gas Sensor
- CO
- 0-1000ppm, Max 1500ppm
- Read More
ME4-CO-E4 Carbon Monoxide Gas Sensor
- CO
- 0-1000ppm, Max 2000ppm
- Read More
ME3-CO Carbon Monoxide Gas Sensor
- CO
- 0-1000ppm, Max 2000ppm
- Read More
ME2-CO-Ф14x50-C Carbon Monoxide Sensor
- Carbon Monoxide (CO)
- 0-1000ppm,Max 2000ppm
- Read More
ME2-CO Electrochemical Carbon Monoxide Sensor
- CO
- 0-1000ppm,Max 2000ppm
- Read More
ME2-CO-Ф14x14 Carbon Monoxide Gas Sensor
- CO
- 0-1000ppm,Max 2000ppm
- Read More
MP-9 CO/CH4 Semiconductor Flat Surfaced Gas Sensor
- CO,CH4
- 50-1000ppm(CO),300-10000ppm(CH4)
- Read More
MP-7 Carbon Monoxide GAS SENSOR
- CO
- 50-1000ppm
- Read More
GM-702B MEMS Carbon Monoxide Gas Sensor
- CO
- 5-5000ppm
- Read More
Help you compare our sensors
Table Overview for Winsen CO sensor
Unsure which sensor to choose, please leave your information or email us sales@winsensor.com
Modle | Detection principle | Characteristics | Target gas | Detection range | Size |
---|---|---|---|---|---|
MEs-CO |
Electrochemical | Low consumption, High precision | CO Carbon Monoxide Gas | 0~1000ppm | |
ZE33 |
Electrochemical | Sound and light alarm output, and PWM digital signal output mode | CO, CH4 | ||
MEu-CO |
Electrochemical | Excellent repeatability and stability | Carbon monoxide(CO) | 0~1000ppm | |
ZE730-CO |
Electrochemical | High temperature resistance, fast response, low power consumption, high precision, long life | Carbon Monoxide | 0~1000ppm | |
MEu-2CO |
Electrochemical | Excellent repeatability and stability | Carbon monoxide(CO) | 0~500ppm,Max Range 1000ppm | |
ME2-CO-Φ14x5 |
Electrochemical | Low consumption,High precision | CO | 0~1000ppm | |
MQ-7B |
Semiconductor | Good sensitivity to CO | CO | 10-500ppm | φ16.7×9.4 |
MQ-9B |
Semiconductor | Good sensitivity to CO | CO,CH4 | CO(10-500ppm),CH4(300-10000ppm) | φ16.7×9.4 |
ZE18-CO |
Module, electrochemical | Household CO gas alarm, smart home devices. | CO | 0~500ppm | 61x14x4.4mm |
ZE16-CO |
Module, electrochemical | Household CO gas alarm, smart home devices. | CO | 0~500ppm | 40x17.30x13.8 |
ZE16B-CO |
Module, electrochemical | Development of household CO gas alarm Detection of CO concentration at residential occasions | CO | 0~500ppm | 28x117mm |
ZE15-CO |
Module, electrochemical | Household CO alarm gas, smart home devices. | CO | 0~500ppm | 25.4x22.4x18.3mm |
ZE07-CO |
Module, electrochemical | Supply UART output, analog voltage output and various of output way | CO | 0~500ppm | 25.4x22.4x18.3mm |
ZE03 |
Module, electrochemical | Supply UART output and analog voltage output; Use for portable and fixed gas detector, various gas detection equipment and occasion. | CO,O2,NH3,H2S,NO2,O3,SO2, CL2,HF,H2,PH3,HCL, etc. | See manual | ø23.5mm*24.5mm |
ZE03G |
Module, electrochemical | Portable and fixed gas detector, various gas detection equipment and situation. | CO, H2S, NH3, CL2, SO2, NO2, O2 and other gases | See manual | ø23.5mm*24.5mm |
ME4-CO |
Electrochemical | Petroleum and petrochemical, metallurgy, mining and other industrial sites and environmental protection fields | CO | 0-1000ppm, Max 1500ppm | φ32×14.5 |
ME4-CO-E4 |
Electrochemical | Urban atmosphere and enterprise environmental monitoring, unorganized emission pollution gas monitoring in factories, emergency monitoring, environmental assessment and monitoring | CO | 0-1000ppm, Max 2000ppm | φ32×14.5 |
ME3-CO |
Electrochemical | Petroleum and petrochemical, metallurgy, mining and other industrial sites and environmental protection fields | CO | 0-1000ppm, Max 2000ppm | φ20×16.4 |
ME2-CO-Ф14x50-C |
Electrochemical | Civil use,low consumption,high precision,high sensitivity,good anti-interference ability | Carbon Monoxide (CO) | 0-1000ppm,Max 2000ppm | φ14×50 |
ME2-CO φ20×16.4 |
Electrochemical | Civil use,low consumption,high precision,high sensitivity,good anti-interference ability | CO | 0-1000ppm,Max 2000ppm | φ20×16.4 |
ME2-CO-Ф14x14 |
Electrochemical | Civil use,low consumption,high precision,high sensitivity,good anti-interference ability | CO | 0-1000ppm,Max 2000ppm | φ20×16.4 |
MP-9 |
Semiconductor | High sensitivity to CO、CH4 | CO,CH4 | 50-1000ppm(CO),300-10000ppm(CH4) | φ9.4×7.5 |
MP-7 |
Semiconductor | High sensitivity to CO | CO | 50-1000ppm | φ9.4×8 |
GM-702B |
Semiconductor、MEMS | High sensitivity to CO | CO | 5-5000ppm | 5×5×1.55 |
- 0086-371-67169097
- sales@winsensor.com
- Mon - Fri 9am - 6pm
ARE YOU LOOKING FOR SENSOR
Not sure which sensor is right?
Get a free initial consultation right now
WHAT WE DO
CO sensor Knowledge
The closed environment make it difficult for air ventilation, and accumulate large amount of CO gas causing damage to people’s health. It’s quite necessary to install detecting device and alarms. Winsen has carbon monoxide gas sensors UL certified used for home kitchen, gas heater, small generator, indoor garage, portable detector, commercial and industrial applications.